<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Nibecker &#38; Associates &#187; Medical Facilities</title>
	<atom:link href="http://nibecker.com/category/projects/medical-facilities/feed/" rel="self" type="application/rss+xml" />
	<link>http://nibecker.com</link>
	<description>Consulting Mechanical Engineers</description>
	<lastBuildDate>Sat, 25 Aug 2012 00:28:28 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.4.1</generator>
		<item>
		<title>St. John’s Regional Medical Center, Oxnard, CA</title>
		<link>http://nibecker.com/st-johns-regional-medical-center-oxnard-ca/</link>
		<comments>http://nibecker.com/st-johns-regional-medical-center-oxnard-ca/#comments</comments>
		<pubDate>Wed, 18 Jul 2012 00:59:41 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Medical Facilities]]></category>

		<guid isPermaLink="false">http://174.120.254.130/~nibecker/?p=169</guid>
		<description><![CDATA[Client: Pedersen Architects Renovation of a 2,600 square foot patient wing Design of medical gas piping systems (medical air, O2, &#38; vacuum) serving outlets in patient rooms Phased shut-down of existing medical gas systems to minimize patient disruptions Client: JSA Architecture &#38; Planning Design of medical gas, HVAC and plumbing systems to serve a new [...]]]></description>
			<content:encoded><![CDATA[<p><img class="alignnone size-large wp-image-170" title="st_johns" src="http://174.120.254.130/~nibecker/wp-content/uploads/2012/07/st_johns-1024x293.jpg" alt="" width="640" height="183" /><br />
Client: Pedersen Architects</p>
<ul>
<li>Renovation of a 2,600 square foot patient wing</li>
<li>Design of medical gas piping systems (medical air, O2, &amp; vacuum) serving outlets in patient rooms</li>
<li>Phased shut-down of existing medical gas systems to minimize patient disruptions</li>
</ul>
<p>Client: JSA Architecture &amp; Planning</p>
<ul>
<li>Design of medical gas, HVAC and plumbing systems to serve a new 900 square foot neo-natal ICU</li>
<li>ICU designed to fit within an existing portion of the hospital requiring careful documentation of the existing HVAC and medical gas system capabilities</li>
<li>Rebalance of central HVAC system serving involved portion of hospital to achieve required air balance at the ICU</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://nibecker.com/st-johns-regional-medical-center-oxnard-ca/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Burnwall Physical Therapy, Oxnard, CA</title>
		<link>http://nibecker.com/burnwall-physical-therapy-oxnard-ca/</link>
		<comments>http://nibecker.com/burnwall-physical-therapy-oxnard-ca/#comments</comments>
		<pubDate>Wed, 18 Jul 2012 00:53:41 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Medical Facilities]]></category>

		<guid isPermaLink="false">http://174.120.254.130/~nibecker/?p=163</guid>
		<description><![CDATA[Client: Johnson + Muller Architects 8,600 square foot physical and aquatic therapy center with adjacent 1,900 square foot leasable tenant space Indoor pool conditioned using a refrigerated dehumidification system with gas heating Single zone unitary HVAC systems serving office and treatment areas Plumbing design for core restrooms, locker rooms, indoor pool area drains, and roof [...]]]></description>
			<content:encoded><![CDATA[<p><a href="http://174.120.254.130/~nibecker/burnwall-physical-therapy-oxnard-ca/img_0775-2/" rel="attachment wp-att-167"><img class="alignleft size-medium wp-image-167" title="IMG_0775" src="http://174.120.254.130/~nibecker/wp-content/uploads/2012/07/IMG_07751-300x279.jpg" alt="" width="300" height="279" /></a>Client: Johnson + Muller Architects</p>
<ul>
<li>8,600 square foot physical and aquatic therapy center with adjacent 1,900 square foot leasable tenant space</li>
<li>Indoor pool conditioned using a refrigerated dehumidification system with gas heating</li>
<li>Single zone unitary HVAC systems serving office and treatment areas</li>
<li>Plumbing design for core restrooms, locker rooms, indoor pool area drains, and roof drains</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://nibecker.com/burnwall-physical-therapy-oxnard-ca/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Los Robles Regional Medical Center, Thousand Oaks, CA</title>
		<link>http://nibecker.com/los-robles-regional-medical-center-thousand-oaks-ca/</link>
		<comments>http://nibecker.com/los-robles-regional-medical-center-thousand-oaks-ca/#comments</comments>
		<pubDate>Wed, 18 Jul 2012 00:50:14 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Medical Facilities]]></category>

		<guid isPermaLink="false">http://174.120.254.130/~nibecker/?p=157</guid>
		<description><![CDATA[Client: Johnson + Muller Architects 5,000 square foot renovation of a physical therapy center Adjusted outside air intake on existing air handler to provide correct ventilation to space New duct distribution layout with specification of reheat to match current air conditioning system Specified room airflows to comply with calculated cooling and heating loads]]></description>
			<content:encoded><![CDATA[<p><img class="alignnone size-full wp-image-158" title="LosRobles" src="http://174.120.254.130/~nibecker/wp-content/uploads/2012/07/LosRobles.jpg" alt="" width="597" height="183" /><br />
Client: Johnson + Muller Architects</p>
<ul>
<li>5,000 square foot renovation of a physical therapy center</li>
<li>Adjusted outside air intake on existing air handler to provide correct ventilation to space</li>
<li>New duct distribution layout with specification of reheat to match current air conditioning system</li>
<li>Specified room airflows to comply with calculated cooling and heating loads</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://nibecker.com/los-robles-regional-medical-center-thousand-oaks-ca/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Body Plan Institute, Santa Barbara, CA</title>
		<link>http://nibecker.com/body-plan-institute-santa-barbara-ca/</link>
		<comments>http://nibecker.com/body-plan-institute-santa-barbara-ca/#comments</comments>
		<pubDate>Wed, 18 Jul 2012 00:49:09 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Medical Facilities]]></category>

		<guid isPermaLink="false">http://174.120.254.130/~nibecker/?p=153</guid>
		<description><![CDATA[Client: Body Plan Institute A 2,600 square foot, single story tenant improvement HVAC system design to serve patient areas, equipment areas, and MRI/ECAM suites Process chilled water piping layout and design of helium quench vent to serve the MRI]]></description>
			<content:encoded><![CDATA[<p><img class="alignleft size-full wp-image-154" title="BodyPlan" src="http://174.120.254.130/~nibecker/wp-content/uploads/2012/07/BodyPlan.gif" alt="" width="402" height="280" /><br />
Client: Body Plan Institute</p>
<ul>
<li>A 2,600 square foot, single story tenant improvement</li>
<li>HVAC system design to serve patient areas, equipment areas, and MRI/ECAM suites</li>
<li>Process chilled water piping layout and design of helium quench vent to serve the MRI</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://nibecker.com/body-plan-institute-santa-barbara-ca/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
